Specifications/Models
Envirolyte(安露來) CIP-20/20
Envirolyte(安露來) CIP-40/40
Envirolyte(安露來) CIP-100/100
Envirolyte(安露來) CIP-200/200
Envirolyte(安露來) CIP-300/300
Output capacity
~20 LpH of ANW anolyte with pH ~ 6.0 - 7.0 (can be regulated) and ~ 500- 550 ppm of FAC;
~20 LpH of catholyte with pH ~ 12,2-12,5 and ~ 0,8- 1,0 g/L of NaOH
~40 LpH of ANW anolyte with pH ~ 6.0 - 7.0 (can be regulated) and ~ 500- 550 ppm of FAC;
~~40 LpH of catholyte with pH ~ 12,2-12,5 and ~ 0,8- 1,0 g/L of NaOH
~100 LpH of ANW anolyte with pH ~ 6.0 - 7.0 (can be regulated) and ~ 500- 550 ppm of FAC;
~~100 LpH of catholyte with pH ~ 12,2-12,5 and ~ 0,8- 1,0 g/L of NaOH
~200 LpH of ANW anolyte with pH ~ 6.0 - 7.0 (can be regulated) and ~ 500- 550 ppm of FAC;
~~200 LpH of catholyte with pH ~ 12,2-12,5 and ~ 0,8- 1,0 g/L of NaOH
~300 LpH of ANW anolyte with pH ~ 6.0 - 7.0 (can be regulated) and ~ 500- 550 ppm of FAC;
~~300 LpH of catholyte with pH ~ 12,2-12,5 and ~ 0,8- 1,0 g/L of NaOH
Production mode
Either independent production of anolyte and catholyte or simultaneous production of both fluids. Operation is controlled by the level switches in anolyte and catholyte tanks
Either independent production of anolyte and catholyte or simultaneous production of both fluids. Operation is controlled by the level switches in anolyte and catholyte tanks
Either independent production of anolyte and catholyte or simultaneous production of both fluids. Operation is controlled by the level switches in anolyte and catholyte tanks
Either independent production of anolyte and catholyte or simultaneous production of both fluids. Operation is controlled by the level switches in anolyte and catholyte tanks
Either independent production of anolyte and catholyte or simultaneous production of both fluids. Operation is controlled by the level switches in anolyte and catholyte tanks
Power supply
220VAC/One phase/ 50-60 Hz
220VAC/One phase/ 50-60 Hz
220VAC/One phase/ 50-60 Hz
380 VAC/Three phase/ 50-60 Hz
380 VAC/Three phase/ 50-60 Hz
Salt consumption to generate ~ 500 ppm of FAC and catholyte with ~1,0 g/L of NaOH
~1,5 g per 1 L of anolyte and ~-3,8 g per 1 L of catholyte
~1,5 g per 1 L of anolyte and ~-3,8 g per 1 L of catholyte
~1,5 g per 1 L of anolyte and ~-3,8 g per 1 L of catholyte
~1,5 g per 1 L of anolyte and ~-3,8 g per 1 L of catholyte
~1,5 g per 1 L of anolyte and ~-3,8 g per 1 L of catholyte
Semi-automated flushing
+
+
+
+
+
Acid pump to flush the cells
+
+
+
+
+
Peristaltic control pump for cathode chamber of anolyte generator
+
+
+
+
+
Peristaltic control pump for anode chamber of catholyte generator
+
+
+
+
+
Peristaltic ontrol pump for Ph regulation of anolyte
+
+
+
+
+
Flow and pressure switches / controllers
+
separate for each platform
+
separate for each platform
+
separate for each platform
+
separate for each platform
+
separate for each platform
Conductivity sensor to control the brine saturation and consumption
+
+
+
+
+
Level switch
+
separate for each platform
+
separate for each platform
+
separate for each platform
+
separate for each platform
+
separate for each platform
Overflow Level switch
Optional
Optional
Optional
Optional
Optional
Overflow sound alarm
Optional
Optional
Optional
Optional
Optional
230 VAC Extra socket in the electrical cabinet
Optional
Optional
Optional
Optional
Optional
Durability
Able to stand up to adverse conditions such as dust and high humidity
Able to stand up to adverse conditions such as dust and high humidity
Able to stand up to adverse conditions such as dust and high humidity
Able to stand up to adverse conditions such as dust and high humidity
Able to stand up to adverse conditions such as dust and high humidity
Type of cells
1 x R-40ANW
1 x R-60C
1 x R-80ANW
1 x R-120C
1 x R-120ANW
1 x R-300C
1 x R-200ANW
1 x R-400C
1 x R-300ANW
1 x R-600C
Life expectancy of electrodes and membrane
~ 5 - 7 years
~ 5 - 7 years
~ 5 - 7 years
~ 5 - 7 years
~ 5 - 7 years
Fittings
LLDPE tubing + Kynar fittings
LLDPE tubing + Kynar fittings
LLDPE tubing + Kynar fittings
LLDPE tubing + Kynar fittings
LLDPE tubing + Kynar fittings
PLC control:
Unitronics/Vision 130 or Vision 280
+
+
+
+
+
Remote control capabilities
Optional
Ethernet or GSM or Modbus – needs to be specified when ordering.
Optional
Ethernet or GSM or Modbus – needs to be specified when ordering.
Optional
Ethernet or GSM or Modbus – needs to be specified when ordering.
Optional
Ethernet or GSM or Modbus – needs to be specified when ordering.
Optional
Ethernet or GSM or Modbus – needs to be specified when ordering.